Product OverView

  • Adjustable voltage sensitivity
    APC BACK-UPS 500VA BX500CI provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
  • Adjustable voltage-transfer points
    Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
  • Audible alarms
    Provides notification of changing utility power and UPS power conditions
  • Automatic self-test
    Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Battery failure notification
    Provides early-warning fault analysis on batteries enabling timely preventive maintenance
  • Boost Automatic Voltage Regulation (AVR)
    Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
  • LED status indicators
    Quickly understand unit and power status with visual indicators.
  • Resettable circuit breaker
    Easy recovery from overloads; no need to replace a fuse.
  • Safety-agency approved
    Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Back-UPSFeatures & Benefits

Protection
  • Surge only outlets
    Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
  • Battery and surge protected outlets
    Back up and protect your hardware and data during power outages, surges and spikes.
Availability
  • Intelligent battery management
    Maximizes battery performance, life, and reliability through intelligent, precision charging.
  • Battery failure notification
    Provides early-warning fault analysis on batteries enabling timely preventive maintenance
  • Automatic self-test
    Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Marketing Features
  • Battery-protected and surge-only outlets
    Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Manageability
  • LED status display
    Quickly understand unit and power status with visual indicators.
  • Audible alarms
    Provides notification of changing utility power and UPS power conditions
Safety
  • Safety-agency approved
    Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Technical Specifications

Output

Output power capacity 300Watts / 500VAMax Configurable Power (Watts) 300Watts / 500VANominal Output Voltage 230VOutput Frequency (sync to mains) 50 HzOutput Frequency (not synced) 50Hz +/- 0.1% for 50Hz nominalTopology Line InteractiveWaveform type Stepped approximation to a sinewaveOutput Connections
(1) IEC Jumpers (Battery Backup)
(3) IEC 320 C13 (Battery Backup)
Transfer Time 6ms typical : 10ms maximum

Input

Nominal Input Voltage 230VInput frequency 45 – 65 HzInput Connections IEC-320 C14Cord Length 1.83metersInput voltage range for main operations 160 – 280VNumber of Power Cords 1Maximum Input Current 2.0A

Communications & Management

Control panel LED status display with On Line : On Battery : Replace Battery and Overload indicatorsAudible Alarm Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm
Surge Protection and Filtering

Surge energy rating 273Joules

Physical

Maximum Height 185mm , 18.5CMMaximum Width 115mm , 11.5CMMaximum Depth 213mm , 21.3CMNet Weight 5.2KGShipping weight 5.68KGShipping Height 257mm , 25.7CMShipping Width 190mm , 19.0CMShipping Depth 291mm , 29.1CMColor BlackMaster Carton Units 2.0Units per Pallet 60.0SCC Codes 6073130430736 7

Environmental

Operating Temperature 0 – 40 °C Operating Relative Humidity 0 – 95 % Operating Elevation 0-3000metersStorage Temperature -15 – 45 °C Storage Relative Humidity 0 – 95 % Storage Elevation 0-15000metersAudible noise at 1 meter from surface of unit 45.0dBA